Reference Guide

Table Of Contents
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC * *
CMC * *
CMC8527
Message Unable to retrieve the server- arg1 memory information.
Arguments arg1 = slot number
Detailed
Description
CMC is unable to obtain the memory information from the server specified in the
message. This occurs if there is no communication between CMC and iDRAC.
Recommended
Response Action
Do the following: 1) Reset iDRAC. 2) Reset CMC. If the issue persists, contact your
service provider.
Category System Health (CMC = Chassis Management Controller)
Severity Severity 2 (Warning)
Trap/EventID 2546
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC * * * *
CMC * * *
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC * *
CMC * *
CMC8528
Message Unable to obtain or send link tuning or flex address data to server- arg1 .
Arguments arg1 = slot number
Detailed
Description
CMC is unable to obtain the link tuning or flex address information for the newly
installed hardware (server, Input Output Module, or Mezzanine card), or is unable
to send the link tuning or flex address information to iDRAC.
Recommended
Response Action
Make sure that the currently installed CMC firmware is the latest. Otherwise, update
the CMC with the latest CMC firmware and retry the operation.
Category System Health (CMC = Chassis Management Controller)
Severity Severity 2 (Warning)
Trap/EventID 2546
285