Reference Guide

Table Of Contents
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC * * * *
CMC * * *
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC * *
CMC * *
CMC8522
Message The Mezz card 2 FRU for the server arg1 is not functioning.
Arguments arg1 = slot number
Detailed
Description
The Mezz card 2 FRU for the server specified in the message is not functioning or
CMC is unable to read it.
Recommended
Response Action
Do the following: 1) Reset iDRAC of the specified server or virtual reseat the server.
2) Reset CMC and wait for a few minutes. If the issue persists, contact your service
provider.
Category System Health (CMC = Chassis Management Controller)
Severity Severity 1 (Critical)
Trap/EventID 2545
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC * * * *
CMC * * *
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC * *
CMC * *
CMC8523
Message The Mezz card 3 FRU for the server arg1 is not functioning.
Arguments arg1 = slot number
Detailed
Description
The Mezz card 3 FRU for the server specified in the message is not functioning or
CMC is unable to read it.
282