Reference Guide

Table Of Contents
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC * *
CMC * *
CMC8514
Message Fabric mismatch is detected in the I/O Module arg1 .
Arguments arg1 = iom slot name
Detailed
Description
This error may occur due to any of the following conditions: 1) Invalid I/O Module
and mezzanine card configuration, where a newly installed I/O Modules fabric type
and the resident mezzanine cards fabric types do not match or are incompatible. 2)
Invalid I/O Module and I/O Module configuration, where a newly installed I/O
Module has a different or incompatible fabric type from an I/O Module already
installed in the fabric.
Recommended
Response Action
Refer to Chassis Management Controller Users Guide for additional information.
Category System Health (CMC = Chassis Management Controller)
Severity Severity 1 (Critical)
Trap/EventID 2545
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC * * * *
CMC * * *
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC * *
CMC * *
CMC8516
Message The I/O Module arg1 did not boot within the expected time.
Arguments arg1 = iom slot name
Detailed
Description
The I/O module may have taken more time to boot than was expected or the I/O
module did not boot.
Recommended
Response Action
Verify the I/O Module is turned on using CMC Web Interface or RACADM CLI and
retry the operation. Otherwise, reinsert the I/O Module and retry the operation. If
the problem persists, contact technical support.
Category System Health (CMC = Chassis Management Controller)