Reference Guide

Table Of Contents
Detailed
Description
Each server model only supports a certain set of backplane configurations. For
unified backplanes or split mode capable backplanes that are in unified mode,
multiple controllers cannot be connected to the same backplane. In unified
backplane situations any controller besides the first will not be operational.
Recommended
Response Action
Make sure that only one RAID controller is connected to the backplane. If the issue
persists, contact your service provider.
Category System Health (CBL = Cable)
Severity Severity 1 (Critical)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC
CBL0007
Message Backplane arg1 arg2 cable and backplane arg3 arg4 cable are swapped.
Arguments arg1 = bay ID, arg2 = cable name, arg3 = bay ID, arg4 = cable name
Detailed
Description
The backplane cables identified in the message need to be connected to the
correct backplane bays.
Recommended
Response Action
Make sure the cables identified in the message are cabled correctly. If the issue
persists, contact your service provider.
Category System Health (CBL = Cable)
Severity Severity 1 (Critical)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC
265