Reference Guide

Table Of Contents
7
CBL Event Messages
CBL0001
Message Backplane arg1 power cable disconnected.
Arguments arg1 = bay ID
Detailed
Description
A backplane signal cable was detected, but the accompanying power cable was
not present.
Recommended
Response Action
Reconnect or replace the power cable. If the issue persists, contact your service
provider.
Category System Health (CBL = Cable)
Severity Severity 1 (Critical)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC
CBL0002
Message Backplane arg1 signal cable disconnected.
Arguments arg1 = bay ID
Detailed
Description
A backplane power cable was detected, but the accompanying signal cable was
not present.
Recommended
Response Action
Reconnect or replace the signal cable for the backplane identified in the message.
If the issue persists, contact your service provider.
Category System Health (CBL = Cable)
Severity Severity 1 (Critical)
262