Reference Guide

Table Of Contents
BOOT017
Message Source argument does not support enable or disable mode.
Detailed
Description
The boot device(s) specified in the source argument used in the operation cannot
be enabled or disabled. This behavior applies to BCV devices and one-time boot.
Recommended
Response Action
Refer to the documentation on validity of operation for the boot device specified.
For more information on the operation, see Lifecycle Controller-Remote Services
documentation.
Category Configuration (BOOT = BOOT Control)
Severity Severity 2 (Warning)
No alerts are applicable for this message
BOOT018
Message Specified Boot Control List is read-only
Detailed
Description
The Boot Control List specified in the operation is read-only and cannot be
modified.
Recommended
Response Action
Refer to the documentation on validity of operation for the Boot Control List
specified. For more information on the operation, see Lifecycle Controller-Remote
Services documentation.
Category Configuration (BOOT = BOOT Control)
Severity Severity 2 (Warning)
No alerts are applicable for this message
BOOT8500
Message Unable to change the BIOS boot order for the Server arg1
Arguments arg1 = slot number
Detailed
Description
Unable to change the BIOS boot order for the server because of a broken
communication between the CMC and iDRAC, or iDRAC is rebooting.
Recommended
Response Action
Reset iDRAC or wait until iDRAC reboots, and retry the operation.
Category Configuration (BOOT = BOOT Control)
Severity Severity 1 (Critical)