Reference Guide

Table Of Contents
Trap/EventID 2171
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC *
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC
VLT0212
Message The disk drive bay arg1 voltage is less than the lower warning threshold.
Arguments arg1 = name
Detailed
Description
System hardware detected an over voltage or under voltage condition. If multiple
voltage exceptions occur consecutively the system may power down in failsafe
mode.
Recommended
Response Action
1) Review system logs for power supply exceptions. 2) Reseat hard disks in the bay.
Reconnect all cables attached to the bay. 3) If the problem persists, contact
technical support. Refer to the product documentation to choose a convenient
contact method.
Category System Health (VLT = Voltage)
Severity Severity 2 (Warning)
Trap/EventID 2170
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC *
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC
VLT0213
Message The disk drive bay arg1 voltage is less than the lower critical threshold.
Arguments arg1 = name
2255