Reference Guide

Table Of Contents
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC *
VDR8
Message arg1 has become degraded.
Arguments arg1 = virtual disk
Detailed
Description
This message occurs when a physical disk in the disk group was removed or when
a physical disk included in a redundant virtual disk fails. Because the virtual disk is
redundant (uses mirrored or parity information) and only one physical disk has
failed, the virtual disk can be rebuilt.
Recommended
Response Action
Configure a hot spare for the virtual disk if it is not already configured. Rebuild the
virtual disk. If a physical disk was removed from the disk group, either replace the
disk or restore the original disk.
Category Storage (VDR = Virtual Disk)
Severity Severity 1 (Critical)
Trap/EventID 4353
OMSA Event ID 2057
OMSA Trap ID 120300
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC * *
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC *
VDR9
Message arg1 consistency check has started.
Arguments arg1 = virtual disk
Detailed
Description
A consistency check operation on a virtual disk has started.
Recommended
Response Action
No response action is required.