Reference Guide

Table Of Contents
Detailed
Description
This message occurs when a physical disk in the disk group was removed or when
a physical disk included in a redundant virtual disk fails. Because the virtual disk is
redundant (uses mirrored or parity information) and only one physical disk has
failed, the virtual disk can be rebuilt. Typically, the virtual disk (E.g. RAID 6) has
multiple redundant disks and there is a problem with one of them.
Recommended
Response Action
Replace the missing or failed physical disk.
Category Storage (VDR = Virtual Disk)
Severity Severity 1 (Critical)
Trap/EventID 4353
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC * *
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC *
VDR57
Message Background Initialization in arg1 corrected medium error.
Arguments arg1 = VD Name
Detailed
Description
A disk media error was detected while the controller was completing a background
task. A bad disk block was identified. The disk block has been remapped.
Recommended
Response Action
Consider replacing the disk. If you receive this alert frequently, ensure to replace
the disk. It is recommended to routinely back up your data.
Category Storage (VDR = Virtual Disk)
Severity Severity 3 (Informational)
Trap/EventID 4355
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC * *
2196