Message arg1 has inconsistent data.
Arguments arg1 = VD Name
Detailed
Description
This alert is provided for informational purposes. The virtual disk has inconsistent
data. This may be caused when a power loss or system shutdown occurs while
data is being written to the virtual disk.
Recommended
Response Action
No response action is required.
Category Storage (VDR = Virtual Disk)
Severity Severity 3 (Informational)
Trap/EventID 4355
OMSA Event ID 2281
OMSA Trap ID 120100
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC * *
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC * *
VDR49
Message arg1 is permanently degraded.
Arguments arg1 = VD Name
Detailed
Description
A redundant virtual disk has lost redundancy. This may occur when the virtual disk
suffers the failure of more than one physical disk. In this case, both the source
physical disk and the target disk with redundant data have failed. A rebuild is not
possible because there is no longer redundancy.
Recommended
Response Action
Replace the failed disks and restore from backup.