Message The battery on arg1 learn cycle has timed out.
Arguments arg1 = controller name
Detailed
Description
The controller battery must be fully charged before the learn cycle can begin. The
battery may be unable to maintain a full charge causing the learn cycle to timeout.
In addition, the battery must be able to maintain cached data for a specified period
of time in the event of a power loss. For example, some batteries maintain cached
data for 24 hours. If the battery is unable to maintain cached data for the required
period of time, then the Learn cycle will timeout.
Recommended
Response Action
Replace the battery pack. The battery is unable to maintain a full charge.
Category Storage (BAT = Battery Event)
Severity Severity 2 (Warning)
Trap/EventID 4274