Category Configuration (UEFI = UEFI Event)
Severity Severity 1 (Critical)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC
CMC
UEFI0263
Message Unable to perform iSCSI boot on connection arg1 because the network cable is not
connected.
Arguments arg1 = number
Detailed
Description
Unable to perform iSCSI boot on the connection identified in the message because
the network cable is not connected.
Recommended
Response Action
Check the network cable connection of the system and retry the operation.
Category Configuration (UEFI = UEFI Event)
Severity Severity 2 (Warning)
No alerts are applicable for this message
UEFI0264
Message Unable to perform iSCSI boot because the iSCSI initiator name is invalid.
Detailed
Description
Unable to perform iSCSI boot because the iSCSI initiator name is invalid.
Recommended
Response Action
Go to System Setup > Network Settings page, make sure there is no typographical
error in the iSCSI Initiator Name field, and retry the operation.
Category Configuration (UEFI = UEFI Event)
Severity Severity 2 (Warning)
No alerts are applicable for this message