Reference Guide

Table Of Contents
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC
BAT0007
Message The storage battery has failed.
Detailed
Description
The PERC RAID controller battery may have failed because of thermal exceptions.
Recommended
Response Action
1) Verify the PERC RAID controller battery installation. 2) Check the system logs for
thermal related issues.
Category System Health (BAT = Battery Event)
Severity Severity 1 (Critical)
Trap/EventID 2225
LCD Message Storage battery has failed. Check battery.
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC *
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC
BAT0008
Message The storage battery is present.
Detailed
Description
None
Recommended
Response Action
No response action is required.
Category System Health (BAT = Battery Event)
Severity Severity 3 (Informational)
Trap/EventID 2227
208