Reference Guide

Table Of Contents
UEFI0146
Message Unable to verify the chassis type via iDRAC and CMC. System configuration may be
incorrect as a result.
Detailed
Description
Unable to verify the chassis type via iDRAC and CMC. System configuration may be
incorrect as a result.
Recommended
Response Action
Do one of the following: 1) Restart the system. 2) Update the iDRAC firmware and
then restart the system. If the issue persists, contact your service provider.
Category System Health (UEFI = UEFI Event)
Severity Severity 2 (Warning)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC
CMC
UEFI0147
Message The system hardware or cabling configuration is invalid.
Detailed
Description
The system hardware or cabling configuration is invalid.
Recommended
Response Action
Do the following: 1) Make sure the system cables, risers, and CPU configuration are
installed correctly. 2) Reseat each PCIe riser and reconnect the cables. For more
information, see the system Owners Manual.
Category Configuration (UEFI = UEFI Event)
Severity Severity 1 (Critical)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
2057