Reference Guide

Table Of Contents
UEFI0133
Message Unable to perform PXE boot because the VLAN settings conflict with that of the
iSCSI device settings.
Detailed
Description
Unable to perform PXE boot because the VLAN settings conflict with that of the
iSCSI device settings.
Recommended
Response Action
Do one of the following: 1) Go to System Setup and change the VLAN
configuration for the PXE device to match that of the iSCSI device. Either both
devices must be configured with VLAN enabled or both devices must be
configured with VLAN disabled. 2) Change the PXE device interface setting to use a
different NIC interface than the NIC interface used by the iSCSI device.
Category Configuration (UEFI = UEFI Event)
Severity Severity 2 (Warning)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC
UEFI0134
Message Unable to allocate Memory Mapped Input Output (MMIO) resources for one or
more PCIe devices because of insufficient MMIO memory.
Detailed
Description
Unable to allocate Memory Mapped Input Output (MMIO) resources for one or
more PCIe devices because of insufficient MMIO memory.
Recommended
Response Action
Do one of the following: 1) Remove unused PCIe card(s) to free up MMIO space. 2)
Go to System Setup and enable the Memory Mapped I/O above 4GB option.
Category Configuration (UEFI = UEFI Event)
Severity Severity 2 (Warning)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
2050