Reference Guide

Table Of Contents
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC
UEFI0105
Message Unable to enable the Cluster on Die (COD) feature because of an unsupported
memory configuration.
Detailed
Description
The Cluster on Die (COD) feature cannot be enabled because of an unsupported
memory configuration.
Recommended
Response Action
Make sure to populate all memory channels in the system with a minimum of one
DIMM per channel. For more information, see the platform Owners Manual.
Category Configuration (UEFI = UEFI Event)
Severity Severity 2 (Warning)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC
UEFI0106
Message One or more memory correctable training errors have occurred on memory slot:
arg1
Arguments arg1 = slot
Detailed
Description
One or more memory correctable training errors have occurred on the memory
slot identified in the message.
Recommended
Response Action
Remove input power to the system, reseat the DIMM module and restart the
system. If the correctable error persists, then replace the faulty memory module
identified in the message.
2035