Reference Guide

Table Of Contents
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC
UEFI0103
Message One or more memory initialization errors have occurred on memory slot: arg1 .
Arguments arg1 = slot
Detailed
Description
One or more memory initialization error have occurred on the memory slot
identified in the message.
Recommended
Response Action
Replace the faulty memory module identified in the message.
Category System Health (UEFI = UEFI Event)
Severity Severity 2 (Warning)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC
UEFI0104
Message The DIMM module on memory slot arg1 is populated out of order in the DIMM
channel.
Arguments arg1 = slot
Detailed
Description
The DIMM module on memory slot identified in the message is populated out of
order in the channel.
Recommended
Response Action
Install DIMM modules in sequential order without skipping any slots in the channel.
For more information, see the platform Owners Manual.
Category Configuration (UEFI = UEFI Event)
Severity Severity 2 (Warning)
2034