Reference Guide

Table Of Contents
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC
UEFI0094
Message Unsupported Non-ECC memory module is installed on memory slot: arg1 .
Arguments arg1 = slot number
Detailed
Description
Unsupported Non-ECC memory module is installed on the memory slot identified
in the message.
Recommended
Response Action
Remove all Non-ECC DIMMs and replace them with ECC DIMMs. For more
information, see the platform Owners Manual.
Category Configuration (UEFI = UEFI Event)
Severity Severity 1 (Critical)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC
UEFI0095
Message A DIMM with unsupported voltage is installed on memory slot arg1 .
Arguments arg1 = Slot
Detailed
Description
A DIMM with unsupported voltage is installed on the memory slot identified in the
message.
Recommended
Response Action
Remove the unsupported DIMM module and replace it with a DIMM with a
supported voltage. For more information, see the platform Owners Manual.
Category Configuration (UEFI = UEFI Event)
Severity Severity 1 (Critical)
2029