Reference Guide

Table Of Contents
UEFI0081
Message Memory size has changed from the last time the system was started.
Detailed
Description
Memory size has changed from the last time the system was started. No action is
required if memory was added or removed.
Recommended
Response Action
If the change is expected, no action is necessary. Otherwise, check the DIMM
population inside the system and memory settings in System Setup for
configuration changes. For more information, see the platform Owners Manual.
Category Configuration (UEFI = UEFI Event)
Severity Severity 2 (Warning)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC
UEFI0082
Message The system was reset due to a timeout from the watchdog timer.
Detailed
Description
The system was reset due to a timeout from the watchdog timer.
Recommended
Response Action
Check the System Event Log (SEL) or crash dumps from Operating System to
identify the source that caused the watchdog timer reset. Update the firmware or
driver for the identified device.
Category System Health (UEFI = UEFI Event)
Severity Severity 1 (Critical)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
2022