UEFI0067
Message A PCIe link training failure is observed in arg1 and device link is disabled.
Arguments arg1 = PCIe device
Detailed
Description
A PCIe link failure is observed in the PCIe device identified in the message and
device link is disabled.
Recommended
Response Action
Do one of the following: 1) Turn off the input power to the system and turn on
again. 2) Update the PCIe device firmware. If the issue persists, contact your service
provider.
Category System Health (UEFI = UEFI Event)
Severity Severity 1 (Critical)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC
UEFI0068
Message The mezzanine card configuration used is not supported on this Chassis.
Detailed
Description
The mezzanine card configuration used is not supported on this Chassis. Server
modules used in different Chassis may require cards with different configuration
properties. For more information, contact your service provider.
Recommended
Response Action
Make sure that a supported mezzanine card is used and retry the operation. For
more information, see the platform Owners Manual of the Chassis available at the
support site.