Reference Guide

Table Of Contents
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC
UEFI0057
Message A Machine-Check Exception (MCE) error has occurred.
Detailed
Description
The MCE is logged during Power-on-Self-Test (POST). MCE could have occurred
during either the current or the previous POST.
Recommended
Response Action
Check the System Event Log (SEL) to identify Machine-Check Exception (MCE)
event source. Resolve the issue identified in the SEL that caused the MCE. For
further information, contact your service provider.
Category System Health (UEFI = UEFI Event)
Severity Severity 1 (Critical)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC
UEFI0058
Message An uncorrectable Memory Error has occurred because a Dual Inline Memory
Module (DIMM) is not functioning.
Detailed
Description
Uncorrectable Memory Error has occurred because a Dual Inline Memory Module
(DIMM) is not functioning.
Recommended
Response Action
Check the System Event Log (SEL) to identify the non-functioning DIMM, and then
replace it.
Category System Health (UEFI = UEFI Event)
Severity Severity 1 (Critical)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
2009