Reference Guide

Table Of Contents
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC
UEFI0055
Message Unable to complete the debranding operation because of the issue(s) displayed
earlier.
Detailed
Description
The debranding process cannot be completed because of the reasons identified on
the computer screen.
Recommended
Response Action
Check the screen display for details of the failure. Retry the debrand process again,
or update the system BIOS and then retry.
Category System Health (UEFI = UEFI Event)
Severity Severity 1 (Critical)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC
UEFI0056
Message A PCIe error has occurred.
Detailed
Description
The PCIe error is logged during Power-on-Self-Test (POST). The error could have
occurred during either the current or the previous POST.
Recommended
Response Action
Check the System Event Log (SEL) to identify the PCIe device that is not
functioning correctly, and then update the device firmware.
Category System Health (UEFI = UEFI Event)
Severity Severity 1 (Critical)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
2008