Reference Guide

Table Of Contents
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC
UEFI0038
Message Unable to communicate with iDRAC because of missing interrupts on the Shared
Memory Architecture (SMA) interface.
Detailed
Description
Unable to communicate with iDRAC because an expected interrupt(s) from the
iDRAC SMA (Shared Memory Architecture) interface did not happen. Continuing to
boot may result in unexpected power loss because of unknown power inventory
and unavailability of features such as active power management, thermal
management.
Recommended
Response Action
Do one of the following: 1) Remove input power from the system, wait for 30
seconds, and re-apply input power. Turn on the system. 2) Update the iDRAC
firmware on the system.
Category System Health (UEFI = UEFI Event)
Severity Severity 1 (Critical)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC
UEFI0039
Message Unable to communicate with iDRAC because of an issue in the iDRAC Keyboard
Controller Style (KCS) Intelligent Platform Management Interface (IPMI).
Detailed
Description
Unable to communicate with iDRAC because of an issue in the iDRAC Keyboard
Controller Style (KCS) Intelligent Platform Management Interface (IPMI). Continuing
to boot may result in unexpected power loss because of unknown power inventory
and unavailability of features such as remote out of band access, active power
management, thermal management, inventory collection, LCD, or system error
reporting.
Recommended
Response Action
Do one of the following: 1) Remove input power from the system, wait for 30
seconds, and re-apply input power. Turn on the system. 2) Update the iDRAC
firmware on the system.