Reference Guide

Table Of Contents
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC
UEFI0023
Message BIOS is unable to send the End of POST message to Management Engine because
the Management Engine is not responding.
Detailed
Description
The End of POST message could not be sent to the Management Engine because
the Management Engine is not responding.
Recommended
Response Action
Remove input power from the system, wait for 30 seconds, and re-apply input
power. Turn on the system.
Category System Health (UEFI = UEFI Event)
Severity Severity 1 (Critical)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC
UEFI0024
Message The Management Engine is not responding.
Detailed
Description
The Management Engine firmware is not responding to the BIOS via the HECI
interface.
Recommended
Response Action
Remove input power from the system, wait for 30 seconds, and re-apply input
power. Turn on the system.
Category System Health (UEFI = UEFI Event)
Severity Severity 1 (Critical)