Reference Guide

Table Of Contents
Severity Severity 2 (Warning)
No alerts are applicable for this message
TMP1000
Message arg1 exceeded the maximum warning threshold.
Arguments arg1 = tempsensor name
Detailed
Description
The enclosure is too hot. A variety of factors can cause the excessive temperature.
For example, a fan may have failed, the thermostat may be set too high, or the
room temperature may be too hot.
Recommended
Response Action
Check for factors that may cause overheating. For example, verify that the
enclosure fan is working. You should check the thermostat settings and examine
whether the enclosure is located near a heat source. Make sure the enclosure has
enough ventilation and that the room temperature is not too hot. Refer to the
enclosure documentation for more diagnostic information.
Category Storage (TMP = Temperature)
Severity Severity 2 (Warning)
Trap/EventID 4210
OMSA Event ID 2100
OMSA Trap ID 105300
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC * *
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC *
TMP1001
Message arg1 has crossed the minimum warning threshold.
Arguments arg1 = tempsensor name
Detailed
Description
The enclosure is too cold.
Recommended
Response Action
Check whether the thermostat setting is too low and whether the room
temperature is too cool.
Category Storage (TMP = Temperature)
1963