Reference Guide

Table Of Contents
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC
TMP0107
Message The memory module arg1 temperature is less than the lower critical threshold.
Arguments arg1 = number
Detailed
Description
Ambient air temperature is too cool.
Recommended
Response Action
Check system operating environment.
Category System Health (TMP = Temperature)
Severity Severity 1 (Critical)
Trap/EventID 2161
LCD Message Memory module <number> temperature is outside of range. Check Fans
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC *
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC
TMP0108
Message The memory module arg1 temperature is greater than the upper warning
threshold.
Arguments arg1 = number
Detailed
Description
Ambient air temperature is too warm or one or more fans may have failed.
Recommended
Response Action
Check system operating environment and review event log for fan failures.
Category System Health (TMP = Temperature)
Severity Severity 2 (Warning)
1941