Reference Guide

Table Of Contents
Recommended
Response Action
Check the Lifecycle Log report to analyze the issue. Review settings and branding
information that the ID module configured, resolve the issue, and then retry the
installation process.
Category Configuration (SYS = System Info)
Severity Severity 2 (Warning)
No alerts are applicable for this message
SYS197
Message Unable to install the OEM ID module because of some issues.
Detailed
Description
The OEM ID module cannot be installed because of some issues.
Recommended
Response Action
Check the Lifecycle Log report to analyze the issue, resolve the issue, and then
retry the installation process.
Category Configuration (SYS = System Info)
Severity Severity 1 (Critical)
No alerts are applicable for this message
SYS8500
Message Delay Auto-throttle sent to arg1 server(s). arg2 arg3
Arguments arg1 = number of servers, arg2 = error string, arg3 = errors
Detailed
Description
The Chassis Management Controller (CMC) sent messages to delay power
throttling to all capable servers in the chassis. This was done because the CMC
firmware was updated or a failover was initiated. If specific server errors are shown
in the message, verify that the iDRAC and Lifecycle Controller firmware versions on
those servers is updated to the most current version available.
Recommended
Response Action
If no errors are shown, no response is required. If errors are listed in the message,
navigate to the named servers and make sure that IDRAC and Lifecycle Controller
firmware versions are the latest available.
Category Audit (SYS = System Info)
Severity Severity 3 (Informational)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
1935