Reference Guide

Table Of Contents
SYS116
Message Unable to determine the status of the power cord.
Detailed
Description
The status of the power cord cannot be determined because of one of the
following reasons: 1) The power cable may not be connected properly or
disconnected. 2) The power cord sensor in the power supply unit has failed.
However, the power supply unit may still function. 3) There is an input power
failure.
Recommended
Response Action
Do of the following to resolve the issue: 1) Reconnect the power cord to the power
supply unit. 2) Replace the power supply unit that has the failed power cord sensor,
with a new power supply unit. 3) Make sure that the input power supply is restored.
Category System Health (SYS = System Info)
Severity Severity 2 (Warning)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC
CMC
SYS117
Message The input power supply is restored.
Detailed
Description
The input power supply is restored to the system.
Recommended
Response Action
No response action is required.
Category System Health (SYS = System Info)
Severity Severity 3 (Informational)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
1900