Reference Guide

Table Of Contents
Arguments arg1 = interface, arg2 = BMC, arg3 = SDR, arg4 = SEL
Detailed
Description
IPMI is supported for identified interface, Baseboard Management Controller
(BMC), Sensor Data Records (SDR), and System Event Log (SEL).
Recommended
Response Action
If any status is not present, power cycle the system, and apply the latest firmware
update packages for Lifecycle Controller and iDRAC.
Category System Health (SYS = System Info)
Severity Severity 3 (Informational)
OMSA Event ID 5012
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC
SYS115
Message The power cord sensor is non-functional.
Detailed
Description
The power cord sensor becomes non-functional because of one of the following
reasons: 1) The power cable may not be connected properly or disconnected. 2)
The power cord sensor in the power supply unit has failed. However, the power
supply unit may still function. 3) There is an input power failure.
Recommended
Response Action
Do of the following to resolve the issue: 1) Reconnect the power cord to the power
supply unit. 2) Replace the power supply unit that has the failed power cord sensor,
with a new power supply unit. 3) Make sure that the input power supply is restored.
Category System Health (SYS = System Info)
Severity Severity 1 (Critical)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC
CMC
1899