Reference Guide

Table Of Contents
the system configuration schema published on delltechcenter.com/lc in the LC
XML Schema Guide.
Category Configuration (SYS = System Info)
Severity Severity 2 (Warning)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC
CMC
SYS050
Message The system configuration XML file for import configuration is not compliant with
schema nesting checks.
Detailed
Description
The system configuration XML file for the import configuration operation is not
compliant with schema nesting checks. Only RAID controllers can have nested
Component nodes up to a maximum nesting depth of three.
Recommended
Response Action
Make sure that the system configuration XML file is compliant with the system
configuration schema published on delltechcenter.com/lc in the LC XML Schema
Guide. Only RAID controllers can have nested Component nodes.
Category Configuration (SYS = System Info)
Severity Severity 2 (Warning)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC
CMC
SYS051
Message The system could not be shut down within the specified time.