Reference Guide

Table Of Contents
Recommended
Response Action
Perform a Virtual Reseat operation, and then retry the operation. To virtually reseat
a server 1) Using the CMC Web UI, go to Chassis Overview > Troubleshooting >
Reset Components, and then select slot for the component identified in the
message and apply the Virtual Reseat or 2) Run the following RACADM command
at the command line interface: "racadm serveraction -f -m sled-<slot number>
reseat".
Category Audit (SWU = Software Change)
Severity Severity 1 (Critical)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC * *
SWU8557
Message Invalid firmware: The uploaded firmware image does not contain a verification
signature.
Detailed
Description
Invalid firmware: The uploaded firmware image does not contain a verification
signature.
Recommended
Response Action
Use a valid firmware image and retry the operation.
Category Audit (SWU = Software Change)
Severity Severity 2 (Warning)
No alerts are applicable for this message
SWU8558
Message Invalid firmware: The uploaded firmware image validation was unsuccessful.
Detailed
Description
Invalid firmware: The uploaded firmware image validation was unsuccessful.
Recommended
Response Action
Use a valid firmware image and retry the operation.
Category Audit (SWU = Software Change)
Severity Severity 2 (Warning)
1846