Reference Guide

Table Of Contents
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC * *
SWC8623
Message Unable to save the I/O Aggregator configuration in arg1 .
Arguments arg1 = slot id
Detailed
Description
The current configuration details of IOA in the slot identified in the message could
not be saved to its startup configuration.
Recommended
Response Action
Power-cycle the IOA and retry the operation.
Category Configuration (SWC = Software Config)
Severity Severity 2 (Warning)
Trap/EventID 10530
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC * * * *
CMC * * *
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC * *
CMC * *
SWC8624
Message The network communication session between CMC and I/O Aggregator cannot be
started on arg1 .
Arguments arg1 = slot id
Detailed
Description
The network communication session between CMC and I/O Aggregator (IOA)
cannot be started because the IOA did not respond.
1817