Reference Guide

Table Of Contents
SWC8621
Message The Chassis Management Controller is unable to process inventory data from the
server in slot arg1 .
Arguments arg1 = slot id
Detailed
Description
The Chassis Management Controller (CMC) is unable to process inventory data
from the server slot identified in the message. This can happen if there is no free
temporary storage in CMC.
Recommended
Response Action
Restart the Chassis Management Controller (CMC). To restart the CMC, start an
SSH session to the CMC and enter the command "racadm racreset". Wait for the
CMC to finish restarting and check if the inventory data is collected. If the issue
persists, contact your service provider.
Category Configuration (SWC = Software Config)
Severity Severity 2 (Warning)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC *
CMC *
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC * *
SWC8622
Message Quick Deploy Profile: Unable to access remote network share and apply assigned
profile to the server in slot arg1 .
Arguments arg1 = slot number
Detailed
Description
The remote network share settings are accessible on the CMC web interface at
Server Overview/Setup/Remote Network Share tab. These settings must be correct
for the CMC to connect to the remote network share and perform the application
of the profile as specified in the Quick Deploy tab on the Profiles page.
Recommended
Response Action
Make sure that the remote network share settings in the CMC are correct and that
the remote share NFS/CIFS server is functioning correctly. Use the "Test Network"
button in the CMC Web interface to make sure that the CMC can access the
remote share.
Category Configuration (SWC = Software Config)
Severity Severity 2 (Warning)
1816