Reference Guide

Table Of Contents
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC * *
SWC8522
Message Chassis Group Leader update of member arg1 configuration successful.
Arguments arg1 = member id
Detailed
Description
Successfully completed a configuration sync with the member identified in the
message.
Recommended
Response Action
No response action required.
Category Audit (SWC = Software Config)
Severity Severity 3 (Informational)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC * *
SWC8523
Message Unable to complete Chassis Group Leader update of member arg1 .
Arguments arg1 = DNS or IP address
Detailed
Description
Unable to complete a configuration sync with the member identified in the
message.
Recommended
Response Action
Check the communications between the Chassis Group Leader and the member.
Run the RACADM command "racadm ping <DNS or IP address> " to check the
communications. If the communications are not functional, resolve the
communications issue. If the communications are functional, remove the member
from the group and re-add the member. If the issue persists, contact your service
provider.
Category Audit (SWC = Software Config)
Severity Severity 1 (Critical)
1792