Reference Guide

Table Of Contents
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC
SWC0076
Message The following iDRAC internal storage partitions present in the system were not
mounted during the system startup: arg1
Arguments arg1 = partitions
Detailed
Description
Lifecycle Controller detected that the iDRAC internal storage partitions identified in
the message were not made available by BIOS during the boot process.
Recommended
Response Action
No response action required. If the issue occurs consistently during system startup,
restart the iDRAC and then restart the system. If the issue persists, contact your
service provider.
Category Configuration (SWC = Software Config)
Severity Severity 3 (Informational)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC
SWC0077
Message Unable to initiate the Repurpose or Retire System operation.
Detailed
Description
iDRAC is unable to initiate the Repurpose or Retire System operation because the
iDRAC is not responding or another operation is in progress.
Recommended
Response Action
Retry the operation. If the problem persists, do one the following: 1) Check if there
are other operations running on the iDRAC and wait for the operations to
complete, and retry the operation. 2) Restart the server, and retry the operation.
Category Configuration (SWC = Software Config)
Severity Severity 1 (Critical)
1700