Reference Guide

Table Of Contents
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC * * * *
CMC * * *
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC * *
CMC * * *
STOR16
Message The storage sled arg1 configuration is normal.
Arguments arg1 = slot number
Detailed
Description
The configuration of the storage sled in the slot identified in the message is normal.
Recommended
Response Action
No response action is required.
Category Storage (STOR = Storage)
Severity Severity 3 (Informational)
Trap/EventID 4179
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC * * * *
CMC * * *
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC * *
CMC * * *
STOR17
Message The fault-tolerant pair of RAID controllers arg1 and arg2 can have issues in their
PCIe fabric because both controllers are on the same PCIe fabric.
Arguments arg1 = RAID controller 1, arg2 = RAID controller 2
Detailed
Description
The two RAID controllers are on the same PCIe Fabric. This means that an issue
with a single PCIe switch or Mezzanine card could result in the loss of all storage
functionality from this pair of controllers.
1612