Reference Guide

Table Of Contents
STOR14
Message The peripheral sled in slot arg1 initialization is not complete.
Arguments arg1 = slot number
Detailed
Description
Peripheral sled initialization is not successful with following possible reasons: 1)
FRU is not functioning. 2) Sled internal components are not responding. 3)
Component power state is not good. 4) Hardware configuration errors.
Recommended
Response Action
Do the following: 1) Check system log for further information about the issue, 2)
Remove and re-insert the peripheral sled identified in the message or virtual reseat
the sled, 3) Reset the CMC and wait for a few minutes for the CMC to finish
restarting. If the issue persists, contact your service provider.
Category Storage (STOR = Storage)
Severity Severity 1 (Critical)
Trap/EventID 4177
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC * * * *
CMC * * *
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC * *
CMC * * *
STOR15
Message The storage sled arg1 is improperly configured.
Arguments arg1 = slot number
Detailed
Description
The storage sled identified in the message was inserted in a location which does
not support split dual host operation mode. The storage sled can functionally work
in the current location with only primary PERC controller enabled.
Recommended
Response Action
Do one of the following: 1) Change the operating mode of the storage sled
identified in the message. 2) Insert the storage sled to a different slot.
Category Storage (STOR = Storage)
Severity Severity 2 (Warning)
Trap/EventID 4178
1611