Reference Guide

Table Of Contents
Category Storage (STOR = Storage)
Severity Severity 3 (Informational)
Trap/EventID 4179
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC *
CMC *
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC * *
STOR13
Message Unable to set the operation mode of the newly inserted storage sled in slot arg1 to
Split Single or Split Dural Host, because the storage sled has only one PERC
controller.
Arguments arg1 = slot number
Detailed
Description
The operation mode of the newly inserted storage sled in the slot identified in the
message cannot be set because the storage sled has only one PERC controller. The
operation mode will only be Join after part replacement.
Recommended
Response Action
Make sure that the newly inserted storage sled has the same number of PERC
controllers as the pervious storage sled so that the new sled will have the same
operation mode after part replacement.
Category Storage (STOR = Storage)
Severity Severity 2 (Warning)
Trap/EventID 4178
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC * * * *
CMC * * *
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC * *
CMC * *
1610