Reference Guide

Table Of Contents
Severity Severity 3 (Informational)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC * *
RDU8519
Message Unable to communicate with peer CMC arg1 .
Arguments arg1 = slot number
Detailed
Description
The communication between the primary and standby CMCs was lost. This may
occur when the CMC identified in the message is restarting, or a firmware update
operation is in progress. If the issue persists, a failover will occur.
Recommended
Response Action
Wait for 10 minutes for: 1)Firmware update operations to complete and 2) The
CMC to finish restarting. If the communication is not reestablished, remove and
reinsert the CMC.
Category Audit (RDU = Redundancy)
Severity Severity 3 (Informational)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC * *
RDU8520
Message CMC arg1 : recovered from unhealthy state
Arguments arg1 = slot number
Detailed
Description
The standby CMC is recovered from unhealthy state by the monitoring daemon.
1421