Reference Guide

Table Of Contents
Detailed
Description
For failover, the standby CMC needs to be present, at the same firmware version as
the primary CMC and healthy. During failover, the active CMC resets and the
standby CMC becomes active. This message is logged when the standby CMC
does not meet this criteria
Recommended
Response Action
Check the status of the standby CMC and make sure the firmware version matches
the primary CMC. Then reseat the CMC and retry the operation. If the issue
persists, contact your service provider.
Category Audit (RDU = Redundancy)
Severity Severity 3 (Informational)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC * *
RDU8512
Message CMC arg1 : firmware versions are different [ arg2 arg3 : arg4 arg5 ]
Arguments arg1 = slot number, arg2 = local fw version, arg3 = factory revision, arg4 = remote
version, arg5 = factory revision
Detailed
Description
The firmware versions of the Active CMC and the Standby CMC are different.
Recommended
Response Action
Update the firmware so that the Active and Standby CMC firmware versions are the
same.
Category Audit (RDU = Redundancy)
Severity Severity 3 (Informational)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC * *
1417