Reference Guide

Table Of Contents
Arguments arg1 = slot number
Detailed
Description
The Active CMC has detected a problem or a low memory condition. It is waiting
for the Standby CMC to reset the Active CMC.
Recommended
Response Action
No response action is required.
Category Audit (RDU = Redundancy)
Severity Severity 3 (Informational)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC * *
RDU8502
Message CMC arg1 cannot go standby since the other CMC is not present or healthy.
Arguments arg1 = slot number
Detailed
Description
For failover to occur, the standby CMC needs to be present, at the same version as
the primary and healthy. During failover, the active CMC resets and the standby
CMC becomes active. This message is logged when the standby CMC is absent,
unhealthy or at a different firmware version.
Recommended
Response Action
Check the status of the standby CMC and make sure the firmware version matches
the primary CMC. Then reseat the CMC and retry the operation. If the issue
persists, contact your service provider.
Category Audit (RDU = Redundancy)
Severity Severity 3 (Informational)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC * *
1413