Reference Guide

Table Of Contents
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC *
RDU0013
Message Power supply redundancy is degraded.
Detailed
Description
The current power operational mode is non-redundant because of a power supply
exception, a power supply inventory change, or a system power inventory change.
The system was previously operating in a power redundant mode.
Recommended
Response Action
Check the event log for power supply failures. Review system configuration and
power consumption.
Category System Health (RDU = Redundancy)
Severity Severity 2 (Warning)
Trap/EventID 2474
LCD Message PSU redundancy degraded. Check PSU cables
OMSA Event ID 5305
OMSA Trap ID 5305
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC *
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC *
RDU0014
Message The power supplies are not redundant.
Detailed
Description
The current power supply configuration does not meet the platform requirements
to enable redundancy. If a power supply fails the system may shut down.
Recommended
Response Action
If unintended, review system configuration and power consumption and install
power supplies accordingly. Check power supply status for failures.
Category System Health (RDU = Redundancy)
Severity Severity 3 (Informational)
1404