Reference Guide

Table Of Contents
Detailed
Description
The file type specified (with the t parameter) is invalid. The temperature history can
be exported in XML or CSV.
Recommended
Response Action
Change the requested export file type to either XML or CSV. To do this, change the
argument given to the t parameter. The argument given to the parameter is case-
insensitive.
Category Configuration (RAC = RAC Event)
Severity Severity 3 (Informational)
No alerts are applicable for this message
RAC922
Message Specified path is too long.
Detailed
Description
The specified path (specified with the l parameter) for the remote share is too long.
This path should be less than 256 characters in length.
Recommended
Response Action
Try the same command with a different remote share location, which is less than
256 characters in length.
Category Configuration (RAC = RAC Event)
Severity Severity 2 (Warning)
No alerts are applicable for this message
RAC923
Message The file path is too long.
Detailed
Description
The specified file path (specified with the f parameter) is too long. This path should
be less than 64 characters in length.
Recommended
Response Action
Try the same command with a shorter file path (specified with the f parameter)
which is less than 64 characters in length.
Category Configuration (RAC = RAC Event)
Severity Severity 2 (Warning)
No alerts are applicable for this message
RAC924
Message Inlet temperature history exported successfully.
Detailed
Description
The inlet temperature history was successfully exported to the specified file.
Recommended
Response Action
No response action is required.
1364