Reference Guide

Table Of Contents
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC
CMC
RAC1128
Message The -l option must be specified if -u and -p options are used.
Detailed
Description
Any operation involving remote share (CIFS) cannot continue if the location (-l
option) is not specified. The -u and -p options represent the user name and
password for the remote share, and -l represents the location of the remote share.
Recommended
Response Action
Make sure to specify the location (-l option) of the remote share along with the
user name and password, and retry the operation. To view the list of options that
can used for the required subcommand, run the RACADM command "racadm help
<subcommand>".
Category Configuration (RAC = RAC Event)
Severity Severity 2 (Warning)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC
CMC
RAC1129
Message Unable to modify the BootOnce object.
Detailed
Description
The BootOnce object could not be modified, because the FirstBootDevice object is
set to either F10, F11, or BIOS.
Recommended
Response Action
Configure the FirstBootDevice object to values other than F10, F11, or BIOS and
retry the set operation for the BootOnce object. For more information about
possible FirstBootDevice values, run the RACADM command "racadm help
idrac.serverboot.firstbootdevice".
1332