Reference Guide

Table Of Contents
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC
CMC
RAC1114
Message Configuration XML file preview operation job is initiated. Job ID = arg1
Arguments arg1 = job ID
Detailed
Description
The configuration XML preview operation was successfully initiated and has
generated a job with the job ID identified in the message.
Recommended
Response Action
Monitor the status of the preview operation job by running the racadm command
"racadm jobqueue view -i <job ID>".
Category Configuration (RAC = RAC Event)
Severity Severity 3 (Informational)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC
CMC
RAC1115
Message Unable to run the command, because of insufficient user privileges.
Detailed
Description
The command could not be successfully run, because of insufficient privileges for
the username supplied.
Recommended
Response Action
Make sure that you have appropriate privileges, and then retry the operation.
Category Configuration (RAC = RAC Event)
Severity Severity 3 (Informational)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
1327