Reference Guide

Table Of Contents
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC
CMC
RAC1070
Message Unable to set the maximum non critical threshold value of arg1 , because the value
entered is greater than, or equal to the maximum critical threshold value.
Arguments arg1 = System Board Inlet Temp
Detailed
Description
The maximum non critical threshold value identified in the message cannot be set,
because the value entered is greater than or equal to the maximum critical
threshold value.
Recommended
Response Action
Check the maximum critical threshold level using an appropriate RACADM
command. For example, to view the maximum critical threshold value of a sensor,
run the racadm getsensorinfo command at the command line interface, and then
retry the operation. For more information about other RACADM commands, run
the racadm help command.
Category Configuration (RAC = RAC Event)
Severity Severity 2 (Warning)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC
CMC
RAC1071
Message Unable to set maximum non critical threshold value of arg1 , because the value
entered is less than, or equal to the minimum non critical threshold value.
Arguments arg1 = System Board Inlet Temp
Detailed
Description
The maximum non critical threshold value identified in the message cannot be set,
because the value entered is less than or equal to the minimum non critical
threshold value.
Recommended
Response Action
Check the minimum non critical threshold level using an appropriate RACADM
command. For example, to view the minimum non critical threshold value of a
sensor, run the racadm getsensorinfo command at the command line interface,
1322