Reference Guide

Table Of Contents
RAC1058
Message Rollback operation did not complete successfully because Lifecycle Controller is
disabled.
Detailed
Description
The requested firmware Rollback operation did not complete successfully because
Lifecycle Controller is disabled.
Recommended
Response Action
Run the RACADM command "racadm set
LifecycleController.LCAttributes.LifecycleControllerState 1" to enable Lifecycle
Controller, and retry the operation.
Category Configuration (RAC = RAC Event)
Severity Severity 3 (Informational)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC
CMC
RAC1059
Message Rollback operation could not be performed because another firmware update job
is running.
Detailed
Description
The requested firmware rollback operation could not be performed because
another firmware update job is running or being scheduled.
Recommended
Response Action
Wait until the existing firmware update jobs are completed or scheduled before
retrying the operation. To monitor the status of the existing jobs, run the RACADM
command "racadm jobqueue view". If the issue persists, restart the iDRAC and then
retry the operation after the iDRAC has finished restarting.
Category Configuration (RAC = RAC Event)
Severity Severity 3 (Informational)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
1316