Reference Guide

Table Of Contents
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC
CMC
RAC1017
Message Successfully modified the object value and the change is in pending state.
Detailed
Description
Any staged operation requires a job and system reboot to apply the object values.
Recommended
Response Action
To apply modified value, create a configuration job and reboot the system. To
create the commit and reboot jobs, use "jobqueue" command. For more
information about the "jobqueue" command, see RACADM help.
Category Configuration (RAC = RAC Event)
Severity Severity 3 (Informational)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC
CMC
RAC1018
Message The specified object or syntax is invalid.
Detailed
Description
This occurs when an incorrect syntax is used or an incorrect object is specified
during the command invocation.
Recommended
Response Action
Make sure to use the correct syntax and correct object names, and retry the
operation. For information related to the corresponding group, see RACADM help
or the RACADM Users Guide.
Category Configuration (RAC = RAC Event)
Severity Severity 2 (Warning)
1296