AMP402
Message The arg1 sensor returned to a normal state with a value of arg2 A.
Arguments arg1 = sensor name, arg2 = current
Detailed
Description
The current sensor identified in the message has returned to a normal state.
Recommended
Response Action
No response action is required.
Category System Health (AMP = Amperage)
Severity Severity 3 (Informational)
OMSA Event ID 5202
OMSA Trap ID 5202
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC *
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC
AMP403
Message The arg1 sensor state has changed to a warning state with a value of arg2 A.
Arguments arg1 = sensor name, arg2 = current
Detailed
Description
The current sensor identified in the message is faulty or the current drawn by the
system exceeds the warning threshold. This condition can cause system
performance issues and degradation in the monitoring capability of the system.
Recommended
Response Action
Verify the Embedded System Management (ESM) Log for any sensor related faults.
If there is a failed sensor, replace the system board. For more information, contact
your service provider. Otherwise, change the warning threshold for the current
sensor such that it corresponds to the hardware configuration.
Category System Health (AMP = Amperage)
Severity Severity 2 (Warning)
OMSA Event ID 5203
OMSA Trap ID 5203