Reference Guide

Table Of Contents
RAC0750
Message Unable to access the USB NIC IP address by using PING process.
Detailed
Description
The USB NIC IP address cannot be accessed by using the PING process.
Recommended
Response Action
Enter another appropriate IP address, and then retry the operation.
Category Configuration (RAC = RAC Event)
Severity Severity 2 (Warning)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC
CMC
RAC0751
Message The threshold value entered is less than the lower warning or critical threshold.
Detailed
Description
The value for information or warning threshold should not be less than lower
critical threshold value.
Recommended
Response Action
Enter a threshold value that is greater than the lower warning or critical threshold
values and retry the operation.
Category Configuration (RAC = RAC Event)
Severity Severity 2 (Warning)
No alerts are applicable for this message
RAC0752
Message The threshold value entered is greater than the upper warning or critical threshold.
Detailed
Description
The value for information or warning threshold should not be greater than upper
critical threshold value.
Recommended
Response Action
Enter a threshold value that is lower than the upper warning or critical threshold
values and retry the operation.
Category Configuration (RAC = RAC Event)
1277